Basic Drugs in Urine - On-Line Analysis with TOX.I.S.™
Reagent Kit, Order Number: 60000
This ClinRep® Complete Kit is intended for use with the TOX.I.S.™ System from Shimadzu, an on-line HPLC system, which has been designed for automated drug screening (on-line analysis).The analytical method allows for the reliable screening of more than 300 illegal basic* drugs, such as morphine, methadone, and amphetamine.*For the drug screening of benzodiazepines, a group of acidic, neutral, and weak basic substances, an additional reagent kit is available (order no. 60100). |
|
Shimadzu TOX.I.S.™ / ClinRep® Reagent Kit |
||
RECIPE and Shimadzu are offering a complete solution for the screening of illegal drugs in urine.The TOX.I.S.™ system from Shimadzu is an on-line HPLC-system with photodiode array detection. It has been designed for the qualitative (and semiquantitative) screening on acute poisoning, drug abuse and doping.The RECIPE reagent kit ensures a reliable and standardised HPLC analysis with Shimadzu’s TOX.I.S.™ system and contains buffers, an internal standard, and a test solution. Also, columns and accessories are provided.The analytical method from Shimadzu allows for an automated sample extraction of more than 300 alkaline drugs of abuse, such as morphin, methadone, and amphetamine. The analyte identification bases on the comparison of retention times and on the comparison with the data of UV spectra libraries. For this purpose, the evaluation software of the system provides an appropriate UV spectra library. Additional compounds can be identified using a spectra library of toxicological relevant substances with approx. 3000 records. |
||
Shimadzu TOX.I.S.™ |
Chromatogram of the ClinTest® Test Solution |
|
![]() |
![]() |
|
| MDA: 21.33 min, Amphetamine: 21.82 min, 6-Acetylmorphine: 23.64 min, Methadone: 24.87 min, Morphine: 26.27 min, Tilidine: 27.88 min, Codeine: 31.81 min, EDDP: 35.45 min, Internal Standard: 40.09 min | ||
|
||
Basic Drugs in Urine - On-Line Analysis with TOX.I.S.™
Reagent Kit, Order Number: 60000
Ordering Information
| Order No. | Description | Quantity |
| 60000 | ClinRep® Reagent Kitfor the TOX.I.S.™ System of Shimadzu for 100 assays | 1 pce. |
| Components of the reagent kit (order no. 60000): | ||
| 60007 | Mobile Phase A | 1700 ml within the kit: 2 x order no. 60007 |
| 60008 | Mobile Phase B | 2000 ml within the kit: 3 x order no. 60008 |
| 60009 | SPE-Buffer | 2500 ml |
| 60012 | IS Internal Standard | 50 ml |
| 60014 | Test Solution | 15 ml within the kit: 2 x order no. 60014 |
| 60021 | SPE-Washing Solution | 1700 ml within the kit: 2 x order no. 60021 |
| Additional Components: | ||
| 60006 | Mobile Phase AB | 2500 ml |
| Start Accessories: | ||
| 60030 | Analytical column with test chromatogram | 1 pce. |
| 60031 | SPE-Column Holder incl. 1 SPE-Column | 1 pce. |
| 60032 | SPE-Column | 1 pce. |
| 60033 | Guard Column Holder incl. 1 Guard Column | 1 pce. |
| 60034 | Guard Columns | 10 pcs. |
| FK5820 | Stainless steel prefilter holder | 1 pce. |
| FK5821 | Replacement filter for stainless steel prefilter holder | 10 pcs. |