iris tech
iris technologies international gmbh
RECIPE products
- ClinRep© | Clinical Diagnostics |
HPLC
Complete Kits - ClinRep© | Therapeutic Drug Monitoring | HPLC
Complete Kits
- ClinTox© | Human Bio-
monitoring | HPLC
Complete Kits - ClinMass© | LC-MS/MS
- ClinCal© Matrix Calibrators
- ClinChek© Matrix Controls
- ClinTest© Solutions
- RECIPE News
BIOTICA products
MINERVA products
Catecholamines in Plasma
Complete Kit,
Order No. 1000
Epinephrine, norepinephrine and dopamine are termed as catecholamines. The determination of catecholamines is primarily used for helping to detect and rule out pheochromocytomas in symptomatic patients, i.e. in patients with persistent hypertension. It is also used in order to help monitor for recurrence when a pheochromocytoma has been discovered and removed.For these purposes the present ClinRep® complete kit allows a quick and safe quantification of the catecholamines. The kit is easy to use and is characterized by an extraordinary good lower detection limit. |
|
Test Data |
HPLC Parameters |
|||||||||||||||||||||||||||||||||||||
|
|
Sample Preparation

Chromatograms |
||
| ClinChek® Plasma Control, Level I | ClinCheck® Plasma Control, Level II | |
![]() |
![]() |
|
| Norepinephrine: 4.28 min, Epinephrine: 5.08 min, IS: 7.55 min, Dopamine: 12.05 min | Norepinephrine: 4.28 min, Epinephrine: 5.07 min, IS: 7.56 min, Dopamine: 12.02 min | |
Catecholamines in Plasma
Complete Kit, Order No. 1000
Ordering Information
| Order No. | Description | Quantity |
| 1000 | ClinRep® Complete Kit for Catecholamines in Plasma for 250 assays for 250 assays |
1 pce. |
| Kit Components (order no. 1000): | ||
| 1210 | Mobile Phase | 1000 ml |
| 1011 | Standard Solution | 10 ml |
| 1012 | IS Internal Standard | 15 ml |
| 1013 | Plasma Calibrator, lyophil. | 5 x 5 ml |
| 1020 | Sample Preparation Columns incl. elution vials | 50 pcs. within the kit: 5 x order no. 1020 |
| 1021 | W Washing Solution | 250 ml within the kit: 3 x order no. 1021 |
| 1022 | E Eluting Reagent | 30 ml |
| Manual | 1 pce. | |
| Quick Reference | 1 pce. | |
| Start Accessories: | ||
| 1030 | Analytical Column with test chromatogram | 1 pce. |
| Accessories: | ||
| 1041 | 2 ml sample vial with cap for storing samples | 50 pcs. |
| 1042 | Sampling system for Plasma Catecholamines (5 ml) | 50 pcs. |
| 1060 | Sample preparation column, empty with frit and cap | 50 pcs. |
| 1061 | 250 µl elution vial with cap | 50 pcs. |
| ClinChek® Controls: | ||
| 8810 | Plasma Control, lyophil., Level I | 10 x 5 ml |
| 8811 | Plasma Control, lyophil., Level II | 10 x 5 ml |
| 8809 | Plasma Control, lyophil., Level I, II | 2 x 5 x 5 ml |